Make sure the phone lines are programmed properly (see Section 4).Over-tightening may damage threads, resulting in reduced terminal contact pressure and difficulty with screw terminal removal.Silent Knight fire alarm control panels contain static-sensitive components.
Always ground yourself with a proper wrist strap before handling any circuits so that static charges are removed from the body. Silent Knight Program Manual Pull StationsWhile installing a fire alarm system may make lower insurance rates possible, it is not a substitute for fire insurance An automatic fire alarm system - typically made up of smoke detectors, heat detectors, manual pull stations, audible warning devices, and a fire alarm control with remote notification capability - can provide early warning of a developing fire. A-1 Two-Wire Smoke Detectors.A-11 Four Wire Smoke Detectors.A-13 Silent Knight Fire Product Warranty and Return Policy SK-5208 Plus Basic Operating Instructions PN 151214 Rev. A. The SK-5208 cabinet can be surface mounted or semi-flush mounted. SK-2190 Accessory Cabinet Used for remote mounting of the SK-5217 Zone Expander. Dimensions: 10-38W x 10-316H x 3D (26.35 cm W x 25.88 cm H x 7.62 cm D). While installing a fire alarm system may make the owner eligible for a lower insurance rate, an alarm system is not a substitute for insurance. If the SK-5208 causes harm to the telephone network, the telephone company will notify the user in advance that temporary discontinuance of service may be required. When advance notice is not practical, the telephone company will notify the user as soon as possible. If the SK-5208 and its accessories are to be used as part of a UL installation, carefully read the UL requirements in this section. To prevent water damage, the following conditions should be AVOIDED when mounting the units: Do not mount directly on exterior walls, especially masonry walls (condensation). Induced noise can interfere with telephone communication or even cause false alarms. Avoid pulling one multiconductor cable for the entire panel. Figure 3-2 Model SK-5208 Board Layout Refer to Section 3.9 for complete description of control panel terminal connections. PN 151204. End-users responsible for maintaining the panel should be able to hear alarms and troubles. Fill in the number of devices that will be used in the system and compute the current draw requirements for alarm and standby. The SK-5208 and SK-5217 limits alarm current to 95mA per zone. The SK-5208 alarm current includes 10 of zones in alarm, but in no case less then three zones per UL864. If you use a battery too small for the installation, the system could overload the battery resulting in the installation having less than the required 24 hours standby power. Do NOT apply power to this panel until all accessories are properly connected. Determine the correct AH rating as per your current load calculation (see 3.6.2). In this case, the SK-5208 will switch phone lines and attempt the call again using the second line.
0 Comments
Leave a Reply. |
Details
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |